Sewage Ejector Pump Code (2023 Requirements)

If you are looking for the codes for sewage ejector pumps, you are in the right spot!

In this guide, you will learn:

  • The 7 essential codes!
  • Why the cover needs to be air-tight
  • The need for a check valve
  • And more...
sewage ejector pump code requirements

As a licensed home inspector, I have inspected quite a few ejection pits over the years.

But exactlywhat is an ejector pit?These pumps are similar to regular sump pumps except that they pump (and sometimes grind) sewage from toilets and not stormwater.

Ejector or grinder pumps are for plumbing fixtures that arelocated below the main sewer lineof the house. Ejection pumps catch the sewage in an air-tight pit, while a pump automatically sends it back up to the main drain line.

The most common problems with ejector pumps include a loose fitting lid where sewer gases escape and a malfunctioning check valve. Keep reading to learn about the7 essential code requirements for sewage ejector pumps!

What You Need To Know About Sewage Ejector Pump Code Requirements

The basics of building code for sewage ejector pumps are designed to keep the pump running properly and to keep sewer gases out of the home.

In this guide, I have summarized the most important codes that I found in the IRC or International Residential Code. TheIRC is known as a model codethat many U.S. states and countries have adopted.

Your local county or city may have some slight variations and you should always check your local code for the final authority. You can read the IRC building code on sewage ejector pumps inSection P3007 Sumps And Ejectors here.

Code 1 - Ejector Pit Cover Requirements

Sewage ejector pumps must have a sealed and air tight cover to prevent sewer gases from flowing into the home.

Regular sump pumps don't need to have an air tight lid, but for obvious reasons, it is unhealthy to have sewer gases seep into the house.

As a home inspector, I usually just try to visually make sure the lid is tight, and I don't usually remove sewage ejector pump lids. This cover should alsobe removable with some screws or bolts. The sump pit cover shouldn't be more than 2-inches below grade or finished flooring.

Read Also >>What Are The Building Codes For Crawl Spaces?

Code 2 - Venting Is Required For Ejection Pits

There must be venting installed when there is a sewer ejector pump in a basement.

Venting should beat least 1-1/4 inch in diameterand air admittance valves are not allowed. Air admittance valves would release sewer gas into the home and is forbidden.

Code 3 - Only Fixtures That Need Pumps Should Be Connected

Plumbing fixtures that can drain to the main sewer line by gravity alone should not be discharged into the sewer ejector pump.

If you are on an upper level of the home and use a toilet, the sewer ejector should not be turning on. Only the fixtures below the main sewer line should be going to the ejector pump.

Code 4 - Check Valve Is Required

sewage ejector pump code requirements (2)

All sewer ejector pumps need to have a check valve and a full open valve.

A check valve allows the liquid to only flow in one direction and prevents it from going back into the sump pit. These valves need to be accessible above the sump pit unless the discharge pipe is buried. If buried, then these valves still need to be accessible by removing a cover.

Read Also >>What Are The Codes For Smoke Detectors?

Code 5 - Ejector Pump Pit Size And Materials

The sewage ejector pit size needs to beat least 18-inches in diameterand at least 24-inches deep.

The material for the sewage pit is most commonly plastic but it can also be made out of tile, concrete, steel, or other approved materials.

Code 6 - Must Use Wye Fitting

The discharge pipe of the sewer ejector or grinder pump should be connected to the main waste line through a wye fitting and it should come in from the top.

If the discharge pipe from the pump connects to the bottom of the horizontal waste line, this is incorrect and not to code.

The wye fitting should also beat least 10 pipe diameters distancefrom the bottom of the main waste stack or other fixture drains.

代码7 -污水Ejector Pump Pipe Size (Higher GPM)

Even though the minimum discharge pipe size is 2-inches for ejector pumps, the pipe needs to be larger for higher capacity pumps.

If the ejector pump has a capacity of30 gallons per minuteor more, then the discharge pipe should be at least 2-1/2 inches. If the ejection pump is46 gallons GPMor more, then the pipe should be at least 3-inches or more.

Read Also >>What Are The Essential Gas Shutoff Valve Codes?

Frequently Asked Questions

How Is An Ejector Pump Different From A Sump Pump?

A sewage ejection pump deals with waste from toilets and sinks that are below the level of the house waste line. The pump is needed to send the waste upwards to the main house drain line. A sump pump only deals with stormwater that seeps around the foundation of the house.

How To Maintain A Sewage Ejector Pump?

维护一个弹射坑包括的基础知识verifying that the lid is air-tight, that the check valve is working properly, the impeller spins freely, the float switch is operating correctly, and that the seals are all good.

What Is The Difference Between A Grinder Pump And Ejector Pump?

A grinder pump is usedto grind the sewage from your homebefore pumping it to the main waste line. A sewage ejector pump doesn't grind it at all and just pumps it.

Read Also >>What Are The Construction Codes For Flexible Gas Lines?

Final Thoughts

The codes for sewage ejector pumps aren't complicated, but they are necessary to ensure the proper operation of your pump.

Probably the most important codes include the requirements on a having an air-tight lid that won't leak gases. Installing a check valve and full open valve is essential.

I hope you enjoyed this guide from Home Inspector Secrets!